[ Identification | Description | Input parameters | Output parameters | Links ]

The PolLambda_monitor Component

Polarisation and wavelength sensitive monitor.

Identification

Description

polarisation along a given normalized m-vector (mx, my, mz) as a
function of wavelength.

Example: Pollambda_monitor(Lmin=1, Lmax=20, nL=20, xwidth=0.1, yheight=0.1, npol=11, mx=0, my=1, mz=0, filename="pollambdaMon.data")

Input parameters

Parameters in boldface are required; the others are optional.
Name Unit Description Default
xwidth m Width of detector 0.1
yheight m Height of detector 0.1
nL 1 Number of bins in wavelength 20
npol 1 Number of bins in Pol 21
restore_neutron 1 If set, the monitor does not influence the neutron state 0
nowritefile 1 If set, monitor will skip writing to disk 0
mx can be negative [1] X-component of monitor vector 0
my can be negative [1] Y-component of monitor vector 0
mz can be negative [1] Z-component of monitor vector 0
Lmin AA Minimum wavelength detected  
Lmax AA Maximum wavelength detected  

Output parameters

Name Unit Description Default
PolL_N  
PolL_p  
PolL_p2  

Links


[ Identification | Description | Input parameters | Output parameters | Links ]

Generated automatically by McDoc, Peter Willendrup <peter.willendrup@risoe.dk> / Wed Nov 23 21:27:24 2022